Surface Area and Pore Size Analyzer Sync 110

Category:

Description

Power

Voltage:                   100V~230V ± 10V

Frequency:              50/60Hz

Maximum power:  300W

Connection:            grounding, single-phase power socket

 

Physical properties-Sync 210A                                              Physical properties – Degasser

Length:                    51cm                                                          Length:               40cm

Width:                     53cm                                                          Width:                35 cm

Height:                    93cm                                                          Height:                67cm

Weight:                   45kg                                                           Weight:               15 kg

Accessories Weight:        31kg

Installation requirements:       L 100 * W60cm (not including space computers taking up)

 

Work environment

Temperature:                            15℃ -40℃

Maximum relative humidity:  30%–60%

 

▪ Surface area measurement:

BET surface area (single -point and multi-point)

STSA

Langmuir surface area

T-plot method the total inner surface area of micro pore

BJH adsorption cumulative surface area of the total pore

BJH desorption cumulative surface area of the total pore

 

▪ Determination of pore volume:

Single point total pore volume

BJH adsorption cumulative total pore volume

BJH desorption cumulative total pore volume

  • plot method the total pore volume of micro porous

 

▪ Determination of average pore size:

Adsorption average pore diameter

BJH adsorption average pore diameter

BJH desorption average pore diameter

The most frequency pore

 

▪ Pore size distribution:

BJH adsorption and desorption differential pore size distribution (dV/dD-D) and (dV/dlogD-D)

BJH adsorption and desorption /integral distribution (or cumulative distribution)

MP method micropore distribution

 

Adsorbed Gas :             Non corrosive gases, such as N2, Ar, Kr, H2, O2, CO2, CO, NH3, CH4, etc.

▪ Pressure Sensor at Analysis Station :  

1000 torr, 1;   Accuracy: ±0.15% (F.S.)

▪ Pressure Sensor at P0 Station :    1000 torr; Accuracy: ±0.15% (F.S.)

▪ Degas System :             4 stations can be pretreated simultaneously under vacuum

                     with heating

▪ Degas Temperature :   Ambient to 400 ℃. Free to set up target temperature

▪ Vacuum Pump :            Two-stage rotary vane mechanical vacuum pump,

 the ultimate vacuum is 6.7*10-2 Pa

▪ Analysis Port :              1 samples tested at the same time

▪ Test Principle :             Gas adsorption by static-volumetric analysis

▪ Measurement Range of Specific Surface Area :    

0.0005 m2/g to the infinity;

 Standard sample repetition is less than ± 1.0%

▪ Test Range of Pore Diameter :    

0.35 nm-500 nm;

 pore repeated deviation is less than 0.2 nm in the accurate analysis of

 porous materials with pore greater than 2 nm

▪ Minimum Pore Volume :     0.0001 cm3/g

▪ Range of Relative Pressure P/P0 :   10-5-0.998

 

 

 

Reviews

There are no reviews yet.

Be the first to review “Surface Area and Pore Size Analyzer Sync 110”

Your email address will not be published. Required fields are marked *