Multistandard Test System SM 4000

The system is designed to perform tests on iron raw material as ore pellets, lumps, sinter etc. according to several Standards. All Test procedures can be performed by same oven and same control system, equipped with proper gas flow meters and proper temperature programs.

Vertical oven is based on 5 separate heating zones with individual temperature control systems and is driven by means of solid state power units and temperature controllers and programmers.

Reaction tubes, made in high temperature alloys, include multiple thermocouples and gas inlet and outlet fittings, providing Standard test conditions.
The Oven can be equipped with a continuous weighing device showing and recording sample weight on digital display and logging unit.

SM 4000 features are:

Accuracy of test temperature during all reaction time
Isothermal temperature distribution in the sample
High accuracy of gases flow rate measurement and control
Accuracy of sample weight (resolution 0.1 g)

SM 4000 provides for automatic operation given by:

Automatic temperature time profile control
Gases input timing
Continuous monitoring of sample weight

Category:

Description

Multistandard Capability
ISO 4696-1
Disintegration
ISO 7215
Relative Reducibility
ISO 4696-2
Reduction Degradation
ISO 4698
Free swelling
ISO 8371
Decrepitation
IS 10823 Sect.1 B – Static
Reduction Degradation
IS 11292
Relative Reducibility
Test Temp.
(°C)
500 900 550 900 700 500 900
Reduction Time
(min)
60 180 30 60 30 60 180
 Gas composition
Mix
A B B B B B
Gas flow rate
(nl/min)
 20 15 15 15  — 20 15
 Sample mass
(g)
500 500  500 18 pellets 500 500 ± 1pc 500
Continuous
Weighing system
Option  Yes Option Yes
 Tumbler TB 3000 Yes Yes  — Yes

Note: SM 4000 can be also equipped with proper hardware and software to run CRI-CSR Test as per ISO 18894, ASTM D 5341 and IS 4023.

Gas Mix Composition %
MIX N2 CO CO2 H2 CH4
A 58 20 20 2
B 70 30
    Control Panel

    control panel

     

    Control panel includes complete top quality control and monitoring instrumentation. Temperature of sample is driven by digital programmer and by multiloop digital controller to obtain best isothermal test condition. A temperature alarm controller assures oven safety cutting off power in case of over temperature.

    Automatic inlet of Nitrogen reaction gas are provided according to temperature program. Gas flow control is obtained by digital mass flow meter for reaction gas and by a rotameter for N2 (as option a mass flow meter also for N2 is included).

    Manual gas control is also possible for checking purpose. Optional weighing system allows continuous monitoring of sample weight. A Touch screen recorder and data logger, and Ethernet connection, provide local and remote recording of test data.

    Specifications
    OVEN:
    Heating elements: Silicon carbide elements (20 elements)
     Heating Zones: 5 heating zones
     Max operating temperature: 1200 °C
     Maximum operating Power: 20 kW
     External thermocouple: “K” type (inconel shielded)
     Inner chamber diameter: 140 mm
     REACTION TUBE:
     Reaction tube type : “Double wall” Type B
     Material: AISI 310
     Inner diameter: 75 mm
     Internal thermocouple: Triple “K” type (inconel shielded)
     GAS CONTROL UNIT:
     Flow rate measuring devices Digital Mass Flow Meters
     Reaction Gas flow rate: Up to 50 nl/min
     Purge Gas composition: 100% N2
     Purge gas Flow rate: Up to 50 nl/min
    SAMPLE WEIGHING UNIT:
     Max weight:  30 kg
     Resolution:  0,1 g
     MAIN POWER:   380 V 3 Ph + Neutral (20 kW max)
    Vertical electric oven

    The electric oven consists of a steel structure placed on a frame and including the silica insulation material. Twenty silicon carbide high temperature heating rod elements are placed horizontally in a stack and are grouped in 5 heating zones to provide separate power control.

    Replacement of heating elements is fast and easy with no need of refractory maintenance so that oven life is very long. Inner high temperature chamber is protected by a quartz tube. The oven can be equipped, as an option, with a weighing system to provide continuous monitoring of sample weight during reduction test.

    multifunctionvertical

    Tumbler system TB 3000

    According to ISO 4696-1, ISO 4696-2, IS 10823 and IS 8167, the sample is tumbled after the reaction in the oven. Number of revolutions is pre-set on a digital counter showing remaining revolutions to the end of tumbling. Automatic stop at end of test is provided. The units are protected by a safety cage with switch on the door. Please refer to the Tumbler System product page for further information.

    tumblersystem

    Auxiliary Equipment

    REACTION TUBE LIFTING ELECTRIC TACKLE

    reaction-tube

    Reaction tube lifting tackle

    • For insertion and removing of the reaction tubes
    • Vertical electric movement
    • Two controlled speeds – low / fast movement
    • Manual horizontal movement on rail
    • Max. weight 60 kg
    • Remote control
    • Rail included
    • Power 230 V 50 Hz

    REACTION TUBE TRIPOD

    reaction tube tripods

    Reaction tube tripods

    Model:

    • TR 2000 – For CRI-RDI reaction tubes

    REACTION TUBE COOLING DEVICES

    Cooling System - Complete - small Cooling System - Detail - smallReaction tube cooling devices

    • Digital Temperature controller
    • Ventilation Fan
    • Auto stop at preset temperature
    • Power 230 V 50 Hz

    Model:

    • CS 2000 – For CRI-RDI reaction tubes

    Sample preparation devices

    Auxiliary equipment for Sample Preparation can be provided together with main instrumentation.

    Available devices are:

    • Jaw Crusher for coke
    • Sample Splitter
    • Testing screen machine (with screening trays)
    • Sieving Machine (with sieves)
    • Sieves (for manual sieving)
    • Thermostatic Oven
    • Digital laboratory scale

    RB Automazione Catalogue 2017

    Download the RB Automazione general Catalogue 2017