Description
TB 7000
According to: ASTM D 3402, ISO 3271, ISO 11256, ASTM E 279, ISO 556, IS 6495, IS 1354
Tumbler device for coke, iron ore and sinter. Geared motor unit driven by frequency converter. Number of revolutions is pre-set on a digital counter showing remaining revolutions to the end of tumbling. Automatic stop at end of test is provided. The unit is protected by a safety cage surrounding the equipment with an opening door. A safety switch is provided on the cage door. The Equipment can be supplied in different configuration according to the specific standard requirement (see table below).
Specification: | Description: |
---|---|
Drums int. dimensions | Diameter: 1000 or 910 or 914 mm Width: 500 or 455 or 457 or 1000 mm |
Revolution speed: | 24 ± 1 or 25 ± 1 R.P.M |
Revolutions pre-set: | 1 ÷ 99999 |
Supply: | 230 V 50/60 Hz |
TB 7000-A | TB 7000-B | TB 7000-C | TB 7000-D | TB 7000-E | |
Standard | ASTM D 3402 | ISO 3271 ISO 11256 IS 6495 |
ASTM E 279 | (Micum /Irsid Test) ISO 556 IS 1354 |
(Half Micum Test) ISO 556 IS 1354 |
Sample | Coke | Iron ores | Iron ore pellets | Coke | Coke |
Internal diameter | 910mm | 1000mm | 914mm | 1000mm | 1000mm |
Internal width | 455mm | 500mm | 457mm | 1000mm | 500mm |
No. of lifters | 2 | 2 | 2 | 4 | 4 |
Revolution speed | 24 ± 1 | 25 ± 1 | 24 ± 1 | 25 ± 1 | 25 ± 1 |
TB 5000 and TB 5000 ISO
According to: ASTM D 5341, ISO 18894, IS 4023
Tumbler device for CSR test consists of a wall mounting double drum system. This configuration allows to perform two sample tests at the same time. Automatic stop at end of test is provided. The unit is protected by a safety cage with switch on the door. Variable frequency drive (TB 5000 –ISO). Number of revolutions pre-set on a digital counter showing remaining revolutions to test end. Automatic stop at end of test is provided. The unit is protected by a safety cage with a safety switch on the door.
Specification: | |
---|---|
Drums int. dimension: | Ø 130 x 700 mm |
Revolution speed: | 20 R.P.M. |
Revolution speed accuracy (ASTM D 5349): | ± 1 RPM |
Revolution speed accuracy (ISO 18894): | ± 0. 1 RPM |
Revolutions pre-set: | 1 ÷ 99999 |
Supply: | 230 V 50/60 Hz |
TB TB 3000
According to: ISO 4696-1, ISO 4696-2, IS 10823
Tumbler device for Reduction Disintegration tests consists of a table double drum system. This configuration allows to perform two sample tests at the same time. Number of revolutions is pre-set on a digital counter showing remaining revolutions to the end of tumbling. Automatic stop at end of test is provided.The unit is protected by a safety cage with switch on the door.
Specification: | |
---|---|
Drums int. dimension: | Ø 130 x 200 mm |
Revolution speed | 30 ± 1 R.P.M. |
Revolutions pre-set : | 1 ÷ 99999 |
Supply : | 230 V 50/60 Hz |
RB Automazione Catalogue 2017
Download the RB Automazione general Catalogue 2017
Reviews